Fume Hood with En14175 Certificate Lab Equipment

Products

Fume Hood with En14175 Certificate Lab Equipment

Fume Hood with En14175 Certificate Lab Equipment

EN14175 European Standard and ASHRAE110-2016 US Standard Fume Hood Lab Equipment.Fume Hood Introduction Service Selectio

Send your inquiry

DESCRIPTION

Basic Info
Model NO. PW-1500
Customized Customized
Condition New
Other Type Walk-in Fume Hood
Worktop Phenolic Resin, Epoxy Resin, Ceramic etc
Other Material PP, FRP, Stainless Steel etc
Certificates SGS En14175
Sash Termpered Glass or Laminated Glass
Control Method Cav and Vav
EU Standard En14175
Us Standard Ashrae110-2016
Transport Package Bubble Film+Hard Cotton+Wooden Package
Specification 1200/1500/1800*850*2600mm
Trademark PENWAY
Origin China
HS Code 8414809090
Production Capacity 1000 Sets / Year
Product Description
EN14175 European Standard and ASHRAE110-2016 US Standard Fume Hood Lab Equipment.Fume Hood Introduction

Service Selection of the proper type of fume hood to use in a lab should be based on the actual requirements. Penway Science fume hood is made of ceramic fiber aluminum, steel.SafetyPlays as a pioneer in lab industryFume hood VAV valveAir differential pressure control system for air output and compensationThird-party on-site inspectionThose four points can make the laboratory to be safeHealthEuropean and US design, integrated frames.The sash slideway, balance weight, communication system all of those are embedded in fume hood`s front aluminum frames.CategoryModular frames design.The front frame is made of aluminum environmental protection material.The back frame is made of high-quality steel plate - BaosteelConstant air volume principle (CAV)Conventional hood: This term is used to describe a constant air volume (CAV) hood, an older, traditinally less elaborate hood design used for general protection of the laboratory worker. Because the amount elaborate hood design used for general protection of the laboratory worker. Because the amount of exhausted air is constant, the face velocity of a CAV hood is inversely proportional to the sash height. That is, the lower the sash, the higher the face velocity. CAV hoods can be installed with or without a bypass provision which is an additional opening for air supply into the hood.Variable air volume vs. constant air volume?• Constant volume is good for small applications, for dedicated exhaust, or for two to four units sharing an exhaust.• Most hoods have "setup" time and "run" time, or are only used on a limited basis. While slightly more expensive to buy, that makes a two-speed exhaust more cost effective in use. Typically, low speed is 50% of high speed. Set the blower on high for setup, low for runtime, or for limited-use purposes.• Hoods should be in close proximity to one another to save money on installing and maintaining the exhaust system.• You can also plan for future hoods to be added to the system. But make sure future expansion is identified in the building plan, so that the whole building exhaust and supply can accommodate future needs. For example, you can buy a blower for a 4-hood system when you're only planning to install two hoods at first. Then just block off your "future" duct until you buy the additional hoods.

Fume Hood Comparison Table
Standard NO.Leakage Rage / ppmAir Velocity / m/sRequirementsAir Exhaust / m3/h at 500mEnergy Comsumption
Domestic StandardJB-T 6412-19990.50.5Basic Need1250100%
US StandardASHRAE 110-20160.050.5Basic Need1250100%
European StandardEN 141750.010.3-0.5Sash Open to 500mm Height60052%
ModelBench-top Low-worktop Bench-topWalk-in
Height 2400mm2600mmCustomized
Width1200mm1500mm1800mm
GlassLGGlass (Laminated Glass)
Inner LinerHPL (Phenolic Compact Laminate)Phenolic Resin Ceramic
WorktopPhenolic Resin Epoxy Resin Ceramic
Receptacle4 pcs6 pcsOthers
Water Supply1 pcs2 pcsOthers
Gas Supply1 pcs2 pcsOthers
Base CabinetSingle Door Cabinet Double Door Cabinet Others

Fume Hood with En14175 Certificate Lab Equipment