Vh-2/Vh5 Series Pharmaceutical Dry Powder Granule Agitator Mixing Machine, Lab V Type Powder Blender Mixer
Scope of application:Suitable for laboratory, research institute, scientific research institutions, etc.Product function
Send your inquiryDESCRIPTION
Basic Info
Model NO. | Vh -2 /VH-5/VH-8/VH-10/VH-30/VH-50Powder Mixer |
Condition | New |
Warranty | <1 Year |
After-sales Service | Video Guide |
Order Number | Vh Series |
Application Area | Medicine, Food and Chemical Industry |
Art.No.(Article Number) | Vh2 5 8 10 20 30 50 1 |
Material Type | Powdery and Granular Materials |
Applicable Material | Dry Powder |
Dynamic Type | Electric |
Discharge Method | Ball Valve Discharge |
Maximum Load | 0.8-500kg |
Forms of Layout | Vertical |
Structural Style | Drum Mixer |
Transport Package | Export Packing |
Specification | 450*230*450 |
Trademark | xushengjixie |
Origin | Hunan, China |
HS Code | 8438200000 |
Production Capacity | 50000/Year |
Product Description
Scope of application:Suitable for laboratory, research institute, scientific research institutions, etc.Product function:It is mainly used for mixing particles with particles, particles with powder, powder with powder and other materials in solid preparation experiment. It is the general mixing equipment of pharmaceutical laboratories. At the same time in pharmaceutical, chemical, food and other industries widely used.Working principle:The laboratory mixer V-barrel consists of two cylinders welded together in a V-shape, the shape of which is asymmetrical with respect to the shaft. Because of the rotating motion, the powder particles in the inclined cylinder, continuous repeated alternation, segmentation, merger; The material is randomly transferred from one V-shaped region to another region, and at the same time, slip occurs among the powder particles, and space is superimposed for many times. The particles are distributed on the newly generated surface, so that the diffusion motion is repeated, so as to achieve the purpose of mixing.Technical parameters:Model specification: VH-2LBarrel volume: 2LWorking volume: 0.8LMotor power: 40WMixer speed: 20r/minDimension: 450*480*500Large load: 0.56kgMixer features:The whole machine is made of 304 stainless steel, in line with food, pharmaceutical, chemical and other requirements. Variable frequency speed control for mixed materials, variable frequency speed 0~27 RPM can be adjusted at will. It is a small V-shaped mixer used in the laboratory.Use tips:1, before use should be carried out an empty running test, before the test should first check the firmness of all the connecting parts of the horizontal V-type mixer, the lubricating oil amount in the reducer and the integrity of electrical equipment, and then close the main switch, through the power supply, empty running test.2. Installation: Place the machine smoothly, install the machine foot, pad flat, so that the machine can run freely.3, before use, the place to be refueled will be well oiled, and then no-load operation, check whether the fasteners are loose, whether the electrical is normal, whether the mechanical operation is normal, if there is an abnormal, repair and debugging.Maintenance method:4. Turn the feeding port to the top, open the feeding cover for feeding, the feeding amount shall not exceed the specified volume, and then close the feeding cover and start the machine to operate. If abnormal conditions are found on the way, it must be stopped for inspection.5, after work or change the variety must be inside and outside the hopper wash clean.1. Laboratory powder mixer is suitable for ambient temperature of -5oC -- 40oC, relative humidity < 90%, appropriate constant temperature, should be placed in a ventilated, dry and clean position.2. It is strictly prohibited for underage children to touch the machine without authorization to avoid accidents.3. The lubrication of the reducer is oil-immersed, and the oil storage must be kept on the oil label, and the oil quality must be kept clean. If it is often used, it is necessary to change the new oil every three months. When replacing, the reducer should be disassembled and cleaned, and the new oil should be added.4, mixer electrical control parts, should be kept clean, sensitive, found fault should be repaired in time.5, after a use or stop, should take out the remaining materials in the V-shaped bucket, brush the residual powder of all parts of the machine. If the outage time is long, must wipe all V-type mixer clean, and cover well with cloth.6, V bucket installation and disassembly should be light, stable installation, light, so as to avoid deformation and damage.7. Check the parts regularly, 1-2 times a month, check the items for the power shaft, transmission, reducer and other moving parts are flexible rotation and wear, found defects should be repaired in time, so that the normal use of mixing function.
Related Products
-
Industrial Vegetable Fruit Dehydration Machine Vegetable Freeze Dryer Freeze Drying Equipment
-
Automatic Chemical Flocculant Powder Dosing System
-
Full Automatic Cosmetic Cream Hand Sanitizer Gel Toothpaste Ointment Tube Packing Machine Medicine Industry Aluminum Tube Filling Sealing Machine
-
10% off Mini Lab Dispersion Kneader/Banbury Mixer for Rubber and Plastic